Superior Analysis of Mg, Al, Si, and P in
Alloys with Handheld XRF


The Innov-X Solution:
Once a challenge for handheld XRF, light element analysis is now available with the use of  Innov-X's silicon drift detector (SDD) based analyzer - the highly accurate Omega Xpress.  Continuing our pioneering approach to portable XRF analysis, Innov-X has integrated a novel, patent pending vacuum technology into the Omega Xpress to optimize the sensitivity and precision of magnesium (Mg), aluminum (Al), silicon (Si) and phosphorus (P) measurements in alloys.

Our unique solution integrates a small vacuum chamber inside the analyzer, sealing the detector, measurement aperture and x-ray tube to ambient air.  Operation is simple:  attach analyzer to portable pump, evacuate chamber for approximately 5 seconds, detach analyzer from pump and you're ready for untethered operation for up to 2 hours.  There is no cumbersome vacuum pump to carry or attach to analyzer during operation.

  omega vac unit

How it Works:
A small pressure sensor inside the analyzer continuously monitors the vacuum quality. When the pressure exceeds acceptable levels, the operator is alerted to re-connect to the portable pump to refresh the internal chamber. The pump is battery powered and completely portable. The operator may also tap the Vacuum Icon on the screen to check the internal pressure.

 

Why it’s Better:
Compare the Innov-X solution to competing portable XRFs. Innov-X offers several advantages:

  1. The Omega Xpress analyzer equipped with vacuum technology offers the best Mg in Aluminum LODs on the market.
  2. There is no need to wear a heavy tank of high pressure compressed gas on your back. Carrying pressurized gas is unwieldy at best, dangerous at worst.
  3. No consummables cost. Based on typical XRF duty cycles, using Helium gas will cost up to $10,000 annually just for helium replenishment.
  4. There is no need to have a vacuum pump constantly attached to the analyzer, which limits portability and ease of use.
  5. In one competing model, the sample face being analyzed is also under vacuum. This means for each sample the operator must bring the front end up to atmospheric pressure, change samples, pump down the chamber. This requirement greatly reduces sample throughput for only modest gains in performance.
 

 

 
 

News Flash!

Helium is becoming increasingly hard to get and prices skyrocket as shortage looms!  

Innov-X's vacuum option eliminates the high cost of helium gas compared to competing portable XRF systems. 

Learn More
[PDF 490 KB]

Download the Aluminum Sortability Guide

Download the Omega Xpress Performance Sheet

 

 

 



 
  Innov-X Systems, Inc.
World Headquarters
100 Sylvan Road, Suite 500
Woburn, MA 01801 USA
T. 1-781-938-5005
F. 1-781-938-0128
info@innovxsys.com
Europe
Kasteleinenkampweg 9R
5222 AX's-Hertogenbosch
The Netherlands
T. +31 (0)73-62 72 590
F. +31(0)73-62 72 599
info@innovx-europe.com
Asia
Room 2108, 21/FL
China Insurance Group Building
141 Des Voeux Road Central
Hong Kong
T. +852 2 515 0999
F. +852 2 505 6129
Australia
Suite 6 Level 3, 215 Euston Rd.
Alexandria, NSW, 2015
Australia
T. +61 2 9577 9500
F. +61 2 9519 1850
info@innovx.com.au
© Innov-X Systems, Inc.